Product Details:
| Measuring Geometrics | 45/0 Image Capture |
| Illuminant Observer | D65&A(10) |
| Sample Storage | 30/350 |
| Measurement Time | 1.8 seconds |
| Measuring Area | 4 and 8mm |
| Display | 4.5cm |
| Altitude | 2000m |
| Polution Degree | 2 |
Product Details:
| Brand | LOVIBOND |
| Model Name/Number | PFXi880/L&AT |
| Automation Type | Automatic |
| Operating Voltage | 220V |
| Display Type | Digital |
Product Details:
| Minimum Order Quantity | 1 Piece |
| Usage/Application | laboratery |
| Brand | Lovibond Tintometer |
| Model Name/Number | PFXeo Spectrophotometer |
| Weight | 5.16 KG |
| Dimension | 301MM W*152mm H*331mm D |
*AUTOMATIC COLOUR Measurement for The Edible oils Market
*Measures Lovibond (R)RYBN,Lovibond RY10:1 & AOSC RY
Additional Information:
Product Details:
| Brand | LOVIBOND |
| Sensors | Tristimulus Detectors,Reference and Sample |
| Size | 3.5 inch |
| Resolution | 320x240 |
| Touchscreen | Resistive |
| Keypad | 3 Key Tactile Membrane |
| Cell Type Filters | W100 Spectrophotometer EC Range Holders |
| Range | 0 - 500 |
| Path Length | 10mm |
Product Details:
| Receiver | Blue-enhanced silicon photodiodes |
| Spectral Range | 400 - 700nm |
| Spectral Interval | 10nm - measured |
| Measuring Time | Approx 2 seconds |
| Lamp Life | Approx 500,000 measurements |
| Display | 3.2 inch backlit Colour Graphic LCD |
| Weight | (1.06 kg) |
Product Details:
| Brand | LOVIBOND |
| Model Name/Number | PFXi-995 |
| Measuring principle | 16interference filters |
| Spectral response | 420-710 nm |
| Bandwidth | 10nm |
| Measurement time | less than 30 seconds |
| Weight | 7.7kg |
Product Details:
| Minimum Order Quantity | 1 Piece |
| taking less than | 30 Second |
| Model | PFXi-880/F |
| Measurement Range | 0 - 500 |
| Path length | Up to 153 mm |
| Power Current | DC 6.3 mA. |
Description:
Single Scale Spectrophotometer for Lovibond RYBN (Red, Yellow, Blue, Neutral)
Ideal for the Colour Measurement of Oils & Fats
Direct Lovibond colour readings with 5 1 / 4 cells
Full support for RCMSi (Remote Calibration and Maintenance via internet)
Optional heated sample chamber for maintaining samples at high temperatures
USB & LAN interface
Robust steel construction with excellent chemical resistance
Easy maintenance with removable sample chamber
The Lovibond PFXi-880/F is the ideal solution for anyone wanting to
measure colour only according to the Lovibond RYBN Colour Scale. The
latest model in the extremely successful PFXi range focusses only on this
specific scale. The PFXi-880/F provides easy-to-use, press-button technology which requires no special skills to operate. The built-in menu guides users through the selection of operating parameters - such as language selection. Thereafter, readings are made with a single key press, taking less than 30 seconds to complete.
In the 1890s, Joseph Lovibond, the founder of The Tintometer Ltd,
developed the original Lovibond Scale, based on a calibrated series of red, yellow, blue and neutral glasses. RCMSi - Save Time, Effort and Money After more than a century, The Tintometer Ltd still manufactures and grades the glass filters used for visual colour measurement in terms of
Lovibond units. It is this unparalleled knowledge and experience that are
embodied into the Lovibond PFXi-880/F.
The scale quoted by others as the Lovibond scale does not guarantee
validated Lovibond Colour readings and may not conform with any visual
instrument for Lovibond Colour.
The PFXi-880/F includes RCMSi technology. This unique feature allows
a calibrated measurement to be taken using an ISO 17025 certified
liquid standard. The spectral response is transmitted to the Lovibond
secure calibration server. On completion of this procedure, a traceable
calibration certificate is made electronically available to the user. The
RCMSi system not only gives the user added confidence that the
instrument is working within tight ISO standards but also reduces the
need for expensive, on-site servicing and preventative maintenance of
the unit.In contrast, The Tintometer Ltd can provide validation reports of correlation between Lovibond values obtained on its automatic instruments
Furthermore, the Lovibond instruments uniquely include long sample
chambers that house cells of up to a 6 path length, enabling the
instrument to obtain direct Lovibond colour readings, without multiplying
errors, with 5 cells.
Automatic Testing vs Visual:
The fundamental difference between the PFXi and the Lovibond
Tintometer Model F is that the Model F is based on subjective, visual
comparison methods (relying to a high degree on the judgment and skill
of the operator and hence their perspective, feelings, beliefs and desires).
The PFXi, however, relies on automatic, non-subjective measurements,
completely unaffected by the judgment of the operator).
With operators inexperienced in colour measurement, visual comparison
can be more time consuming and less precise than the fast automatic
readings taken with a PFXi. Visual agreement between operators at one
site or multiple sites cannot be guaranteed.
Using spectrophotometers, colour communication is accurate and
reliable and consistent. Colour Scales allow exact standards to be
communicated to all.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Minimum Volume | 2 ml |
| Mobility | Fixed |
| Std Glass Filters | 8 Filters |
| Brand | LOVIBOND TINTOMETER |
| Wavelength Range | 400-700 nm |
| Automation Type | Semi-Automatic |
| Resolution | 0.1 Lovibond |
| Optical system | 11 glass-filled nylon |
| Weight | 8.3 kg |
| Dimensions | 330 x 410 x 230mm |
| Path length | Up to 153 mm |
Visual Colorimetry : Lovibond ® Precision:
Glass colour standards housed in durable rack
External, low-voltage regulated power supply
Prismatic optical system provides improved colour matching
Balanced field of view
Diffused tungsten-halogen light source
Replaceable sample chamber liner
Operating Principle:
The Lovibond ® Tintometer is a visual colorimeter designed to optimise the use of Lovibond ® glass filters. It is arranged with two adjacent fields of view, seen through the viewing tube, so that the product in the sample field and a white reflective surface in the comparison field are observed side by side, suitably illuminated. The Lovibond ® glasses are introduced into the comparison field by a simple system of sliding racks, allowing the user to compare the colour of light which is either transmitted through or reflected from the sample with that transmitted through the glasses. A series of neutral glasses in racks is also supplied; these can be introduced into the sample field to dull the colour of products which are too bright to obtain a good colour match using Lovibond ® Red, Yellow or Blue glasses. The racks are varied until a visual colour match is found for the light from the sample and its colour can then be expressed in Lovibond ® units.
Additional Information:
Product Details:
| Minimum Volume | 2 ml |
| Std Glass Filters | 8 Filters |
| Temperature Range | 25 Degree Centigrate,80 Degree C |
| Color | Grey |
| Magnification | 1.9X |
| Measurement Range | 0 -500 |
| Wavelength Range | 320-680 nm |
Product Details:
| Brand | Lovibond |
| Model Name/Number | W600.OG |
| Material | Optical Glass |
| Wavelength Range | 400-680 nm |
| Country of Origin | Made in India |
Product Details:
| Model Name/Number | TG 268 |
| Usage/Application | Laboratory |
| Brand | Lovibond |
| Weight | 350 gm |
| Country of Origin | Made in India |
| Interface | USB RS 232 |